|
TANDEM
COMPACT MODEL R070SSZ REMOTE CONDENSER AIR COOLED SINGLE SCREW COMPRESSOR
CHILLER CAPACITY: 719,236
BTU (59.9 TONS) 44 F LEAVING WATER, 95 F ENTERING AMBIENT AIR. EER:
10.7
THESE
ARE SOME OF OUR STANDARD BENEFITS:
- 2 YEAR PARTS WARRANTY ON THE WHOLE
UNIT.
- OVERSIZED, HIGH EFFICIENCY STAINLESS
STEEL COPPER BRAZED EVAPORATOR.
- STAINLESS STEEL BOLTED FRAME,
CONTROL PANEL AND ACCESS PANELS.
- CASTER ASSEMBLY THAT BOLTS TO
FRAME WITH CASTERS THAT CRANK UP AND DOWN FOR EASY INSTALLATION
AND REMOVAL OF CHILLER.
- SHUT-OFF VALVES ON EVAPORATOR
AND CONDENSER ON MAIN HEADER FOR INDIVIDUAL CHILLER REMOVAL WITHOUT
INTERUPTION TO THE SYSTEM.
- EXTERNAL BUS BAR DUCT WITH COMPRESSOR
CIRCUIT BREAKERS FOR INDIVIDUAL CHILLER REMOVAL WITHOUT INTERUPTION
TO THE SYSTEM.
COMPRESSOR:
One independent 70 hp suction gas cooled Copeland "ROTARY SCREW"
compressor with an EER of 10.7 for years of energy savings, complete
with oil sight glass, cranckcase heater, isolation valves, two steps
of capacity control internal motor overload protection consisting
of winding temperature, phase and wrong rotation, isolation valves,
two steps of capacity control per chiller, 100% 50% and off.
EVAPORATOR:
Oversized, high efficiency 80 ton stainless steel copper braze plate
evaporator insulated outside with 1/2" armaflex insulation,
with an evaporator inlet water temperature sensor, inlet shut-off
valve mounted to the main header and coupled with grooved-end pipe
fittings to the evaporator.
Evaporator water outlet has a flow
sensor and water temperature sensor, shut-off valve mounted to the
main header and coupled with grooved-end pipe fittings to the evaporator.
Water piping in and out is insulated with 1/2" armaflex pipe
insulation.
An
individual chiller can be removed without interruption to the main
header supply and return
water flows by closing the ball valves and undoing the grooved-end
coupling.
CONDENSER:
See quotation for remote air cooled condenser.
CHILLER
CONTROL: Our exclusive
"intelligent chiller control system" surpasses all others
with twelve (12) analogue inputs: eight temperature and four pressure,
two flow sensors, loss of phase and phase reversal, over and under
voltage, phase voltage difference along with four digital inputs,
one for each compressor motor internal sensor, one for pump interlock
or local / remote start.
Our exclusive "control logic"
insures long lasting trouble-free operation with alarm outputs before
failures can occur, automatic compressor sequencing (lead/lag) to
even run time, timed starts to ease inrush current.
Connected to our "master chiller
system control" for staging of 12 chillers with a total 24
steps of capacity control, the “building control system” can monitor
the status of all chillers and change the operating temperature
set point.
With an evaporator flow sensor, we
can prevent freeze-ups before they happen and display the exact
operating capacity in tons of each chiller any time during operation.
Inspection or service is made easy
by displays of all temperature and pressure inputs, evaporator flow,
chiller capacity in tons and super heat of each thermal expansion
valve.
-
Suction
and discharge pressures of each compressor.
-
Suction
and discharge temperatures of each compressor.
-
Evaporator
water inlet and outlet temperatures.
-
Condenser
water or air inlet temperature.
-
Water
out temperature for a second evaporator if required.
-
One
evaporator water flow sensor.
-
One
flow sensor for condenser water flow or for a second evaporator.
-
Six
relay outputs for cycling of compressors, unloading solenoids
or hot gas by-pass solenoid valves for capacity control.
-
Two
relay outputs for alarm fault conditions.
-
Two
0 -10V outputs, one for a motorized condenser water regulating
valve, one for a motorized evaporator water by-pass control
valve, and in future it will be able to control an electronic
hot-gas by-pass valve or electronic thermal expansion valve.
Our "intelligent chiller control
system" insures both trouble-free operation without false trips,
and also that the chiller operates at the highest efficiency all
the time.
REFRIGERATION
COMPONENTS: Refrigeration thermal expansion valve field adjustable,
filter dryer, liquid line solenoid, liquid line sight glass with
moisture indicator, liquid line shut-off valve and hot gas by-pass
shut-off valve if hot gas used. Some of these components are not
used in our competitors’ equipment.
Refrigeration circuits are piped
with ACR type L copper and fittings, circuit is brazed using nitrogen
to keep internal surfaces clean from scale buildup, evacuated and
charged with freon. Each chiller is run tested and includes a "run
test data sheet" for field comparison at chiller start-up.
CONTOL
PANEL: NEMA 1 stainless
steel control panel with compressor contactors, compressor circuit
breakers located in bus-duct panel on top of chiller, two control
transformers (one for each compressor) both with primary and secondary
fuses, red emergency stop push button, control board, two line digital
display and data entry key pad.
Our enclosed three phase 900 amp
Bus Bar Duct System is external to the chiller and includes individual
compressor circuit breakers. Our system allows for individual
chillers to be removed from the main bus for service without
shutting down the operating system.
FRAME:
Rugged 12 ga. bolted stainless steel frame with stainless steel
NEMA 1 control panel and bus duct panel, 20 gauge stainless steel
access panels. The base has cutouts for either a fork lift or pallet
truck and uses two of our bolt-on “caster assemblies”. The casters
can be cranked up and down to move the chiller into place or remove
for service.
SIZE:
54"l x 36"w x 73"h.
WEIGHT:
2,354 lbs.
VOLTAGE:
230/460/575V, 3 phase, 60 hertz.
380V, 3 phase, 50 hertz. Capacity reduction of 0.83 at 50 hertz.
WARRANTY:
2 YEAR parts warranty on the whole unit.
AVAILABLE
OPTIONS:
Two-way and three-way motorized
condenser water flow control valve.
Stainless steel main
header water piping across the back of the chiller.
Sound attenuating panels.
Alternate refrigerants.
Hot gas by-pass for additional
capacity control.
NEMA 12 control panel
|