TANDEM
COMPACT MODEL G020DSZ GLYCOL WATER COOLED DUAL CIRCUIT - DUAL SCROLL
COMPRESSOR CHILLER CAPACITY: 227,869
BTU (19.0 TONS) AT 44 F LEAVING WATER, 105 F ENTERING GLYCOL WATER.
EER: 11.6
THESE
ARE SOME OF OUR STANDARD BENEFITS:
- 2 YEAR PARTS WARRANTY ON THE WHOLE UNIT.
- DUAL REFRIGERATION CIRCUITS.
- OVERSIZED, HIGH EFFICIENCY STAINLESS STEEL COPPER
BRAZED EVAPORATOR.
- OVERSIZED, HIGH EFFICIENCY STAINLESS STEEL COPPER
BRAZED CONDENSER.
- STAINLESS STEEL BOLTED FRAME, CONTROL PANEL AND
ACCESS PANELS.
- CASTER ASSEMBLY THAT BOLTS TO FRAME WITH CASTERS
THAT CRANK UP AND DOWN FOR EASY INSTALLATION AND REMOVAL OF CHILLER.
- SHUT-OFF VALVES ON EVAPORATOR AND CONDENSER ON
MAIN HEADER FOR INDIVIDUAL CHILLER REMOVAL WITHOUT INTERUPTION
TO THE SYSTEM.
- EXTERNAL BUS BAR DUCT WITH COMPRESSOR CIRCUIT
BREAKERS FOR INDIVIDUAL CHILLER REMOVAL WITHOUT INTERUPTION TO
THE SYSTEM.
COMPRESSOR: Two independent suction gas cooled
Copeland "SCROLL" compressors with an EER of 11.6 for
years of energy savings. Each compressor complete with internal
overload thermal protection in motor winding, rubber mounting parts
for vibration free operation, oil sight glass, crankcase heater,
isolation valves, two steps of capacity control per chiller, 100%
50% and off, with automatic sequencing of compressors (lead / lag)
for equal run time, extending compressor life.
EVAPORATOR: Oversized, high efficiency 20 ton
dual refrigeration (10 ton/circuit) stainless steel copper braze
plate evaporator insulated outside with 1/2" armaflex insulation,
with an evaporator inlet water temperature sensor, inlet shut-off
valve mounted to the main header and coupled with grooved-end pipe
fittings to the evaporator.
Evaporator
water outlet has a flow sensor and water temperature sensor, shut-off
valve mounted to the main header and coupled with grooved-end pipe
fittings to the evaporator. Water piping in and out is insulated
with 1/2" armaflex pipe insulation.
An
individual chiller can be removed without interruption to the main
header supply and return water flows by
closing the ball valves and undoing the grooved-end coupling.
CONDENSER: Oversized, high efficiency 20 ton
dual refrigeration circuit (10 ton /circuit) stainless steel copper
braze plate condenser with a condenser inlet water temperature sensor,
shut-off valve mounted to the main header and coupled with
grooved-end pipe fittings to the condenser.
Condenser
outlet side has a shut-off valve mounted to the main header and
coupled with grooved-end pipe fittings to the condenser. Condenser
leaving water temperature can be monitored if a second evaporator
is not used.
The
chiller can operate with dry cooler water/glycol as low as 70 F
entering the condenser, maximizing the compressor efficiency while
maintaining optimum expansion valve performance. This is the
highest energy saving available to-day.
For
water/glycol below 70 F a motorized condenser water flow valve can
be installed and controlled by an exclusive “chiller control system”
maintaining a constant safe operating head pressure.
An
individual chiller can be removed without interruption to the main
header supply and return water flows by closing the ball valves
and undoing the grooved-end coupling.
CHILLER CONTROL: Our exclusive "intelligent chiller control system"
surpasses all others with twelve (12) analogue inputs: eight temperature
and four pressure, two flow
sensors, loss of phase and phase reversal, over and under voltage,
phase voltage difference along with four digital inputs, one for
each compressor motor internal sensor, one for pump interlock or
local / remote start.
Our
exclusive "control logic" insures long lasting trouble-free
operation with alarm outputs before failures can occur, automatic
compressor sequencing (lead/lag) to even run time, timed starts
to ease inrush current.
Connected
to our "master chiller system control" for staging of
12 chillers with a total 24 steps of capacity control, the “building
control system” can monitor the status of all chillers and change
the operating temperature set point.
With
an evaporator flow sensor, we can prevent freeze-ups before they
happen and display the exact operating capacity in tons of each
chiller any time during operation.
Inspection
or service is made easy by displays of all temperature and pressure
inputs, evaporator flow, chiller capacity in tons and super heat
of each thermal expansion valve.
SENSOR
INPUTS:
- Suction
and discharge pressures of each compressor.
- Suction
and discharge temperatures of each compressor.
- Evaporator
water inlet and outlet temperatures.
- Condenser
water or air inlet temperature.
- Water
out temperature for a second evaporator if required.
- One
evaporator water flow sensor.
- One
flow sensor for condenser water flow or for a second evaporator.
OUTPUTS:
-
Six relay outputs for cycling of compressors, unloading solenoids
or hot gas by-pass solenoid valves for capacity control.
- Two
relay outputs for alarm fault conditions.
- Two
0 -10V outputs, one for a motorized condenser water regulating
valve, one for a motorized evaporator water by-pass control valve,
and in future it will be able to control an electronic hot-gas
by-pass valve or electronic thermal expansion valve.
Our "intelligent
chiller control system" insures both trouble-free operation
without false trips, and also that the chiller operates at the highest
efficiency all the time.
REFRIGERATION COMPONENTS: Refrigeration
thermal expansion valve field adjustable, filter dryer, liquid line
solenoid, liquid line sight glass with moisture indicator, liquid
line shut-off valve and hot gas by-pass shut-off valve if hot gas
used. Some of these components are not used in our competitors’
equipment.
Refrigeration
circuits are piped with ACR type L copper and fittings, circuit
is brazed using nitrogen to keep internal surfaces clean from scale
buildup, evacuated and charged with freon. Each chiller is run tested
and includes a "run test data sheet" for field comparison
at chiller start-up.
CONTOL PANEL: NEMA 1 stainless steel control
panel with compressor contactors, compressor circuit breakers located
in bus-duct panel on top of chiller, two control transformers (one
for each compressor) both with primary and secondary fuses, red
emergency stop push button, control board, two line digital display
and data entry key pad.
Our enclosed
three phase 900 amp Bus Bar Duct System is external to the chiller
and includes individual compressor circuit breakers. Our system
allows for individual chillers to be removed from the main
bus for service without shutting down the operating system.
FRAME: Rugged 12 ga. bolted stainless
steel frame with stainless steel NEMA 1 control panel and bus duct
panel, 20 gauge stainless steel access panels. The base has cutouts
for either a fork lift or pallet truck and uses two of our bolt-on
“caster assemblies”. The casters can be cranked up and down to move
the chiller into place or remove for service.
SIZE: 48"l
x 24"w x 73"h.
WEIGHT: 1,166 lbs.
VOLTAGE: 230/460/575V, 3 phase, 60 hertz.
380V,
3 phase, 50 hertz. Capacity reduction of 0.83 at 50 hertz.
WARRANTY:
2 YEAR parts warranty on the whole unit.
AVAILABLE
OPTIONS:
Two-way and three-way motorized condenser water flow control
valve.
Stainless steel main header water piping across the back
of the chiller.
Sound attenuating panels.
Alternate refrigerants.
Hot gas by-pass for additional capacity control.
Semi-hermetic compressors.
NEMA 12 control panel.
|