Modular Chilling Equipment
Tandem Chillers manufactures modular chillers and related
chilling equipment which fall into eight categories: (see Chiller Configuration Designation tables
below).
Water Cooled Modular Chillers
Air Cooled Chillers
Condensing Units
Condenserless Air Cooled Chillers
Free Cooling Units
Remote Air Cooled Condensers
Air Cooled Dry Fluid Coolers
Pump Packages
Cooling Towers
Filtration and Strainer Systems
Water Cooled Chillers
If you have 70° F to 105° F building supply water (cooling tower
water) to use for your condenser cooling, we offer high efficiency modular water cooled chillers. With our oversized brazed
plate evaporators and condensers we offer some of the highest EERs
available today.
Dry Glycol Fluid Cooled Chillers
If you do not have access to a building supply water between 70°
F and 105° F to use for your condenser cooling, we offer modular
glycol/water cooled chillers to be used with our high efficiency
dry fluid coolers. These fluid coolers can be located on the roof
or ground and are designed to operate in ambients as high as 115°
F and up to a 50% ethylene glycol water solution for winter operation.
We also supply temperature control valves, pump packages and expansion
tanks to complete your system.
Remote Condenser Air Cooled Chillers
If you do not have access to building supply water (cooling tower
water), and dry fluid coolers are not an option, we offer high efficiency modular remote air cooled condenser chillers to be used with
our high efficiency air cooled condensers. These condensers can
be located on the roof or ground and are designed to operate in
ambients up to 105° F and down to –20° F during the winter months.
Remote Air Cooled Condensers
Our oversized air cooled condensers are designed for operating in
the toughest conditions and temperature extremes. Our unique coil
support system isolates the refrigerant tubes from the unit, tubes
expand and contract without interference, preventing contact and
friction wear. Designed to operate from 0 F (-17.7 C) with fan cycling
and speed control of the first fan down to –30 F (34 C) ambient
with flooded condenser incorporating a heated receiver and head
pressure control valves to 105 F (40.5 C) summer ambient conditions.
Corrosion resistant components insure long lasting operation. Unit
comes with our exclusive 3-year limited warranty.
Dry Air Cooled Fluid Coolers
We use the same unique support system as the air cooled condenser
and corrosion resistant components to insure long lasting operation.
Fluid coolers are computer selected to reduce the fluid cooler pressure
drop and maximize efficiency. Capacity control is achieved by fan
cycling on the leaving fluid temperature. For winter conditions
below 32 F (0 C) we recommend a 45% ethylene glycol solution be
used to prevent freezing of the coil during winter months. Unit
comes with our exclusive 3-year limited warranty.
Pumping Packages
We supply pump packages with horizontal or vertical pumps, 1750
or 3500 rpm TEFC motors, single or stand-by pumps with suction and
discharge headers. Pump packages can be supplied pre-piped with
all necessary shut-off valves, flow control valves, pressure gauges,
thermometers, expansion tank, inlet strainers, temperature operated
or motorized control valves and with a NEMA 1 or 12 control panel
pre-wired to pump motors. Control panels are UL or CSA approved.
Table 1 - Chiller Configuration Designation
CHILLER CONFIGURATION |
- |
A |
030 |
S |
Z |
Z |
A |
Condenser |
Capacity |
Circuit |
Compressor |
Refrigerant |
Voltage |
A = Air Cooled |
020 = 20 Tons |
S = Single Circuit |
R = Reciprocating |
Z = R-22 |
A = 460/3/60 |
H = Heat Reclaim |
030 = 30 Tons |
D = Dual Circuit |
S = Screw |
Y = R-134A |
B = 575/3/60 |
R = Remote Air-Cooled |
050 = 50 Tons |
a |
T = Tandem Scrolls |
X = R-404A |
C = 208/3/60 |
W = Water Cooled |
075 = 75 Tons |
a |
Z = Scroll |
W = R-407C |
D = 230/3/60 |
G = Glycol Cooled |
090 = 90 Tons |
a |
a |
V = R-410 |
F = 380/3/50 |
a |
a |
a |
a |
a |
G = 415/3/50 |
a |
a |
a |
a |
a |
J = 200/3/50 |
a |
a |
a |
a |
a |
M = 380/415/3/50 |
- |
Table 2 - Control Configuration Designation
CONTROL CONFIGURATION |
- |
M |
H |
2 |
Board |
Type |
Stages |
M = Master |
C = COMPRESSOR |
1 = 1 |
S = Slave |
U = CYLINDER |
2 = 2 |
|
H = HOT GAS |
3 = 3 |
|
S = SPECIAL |
4 = 4 |
- |
Table 3 - Condenser Configuration Designation
CONDENSER CONFIGURATION |
- |
H |
CONTROL |
CONDENSER TYPE |
T = T Stat
F = Fan Speed
H = Head Pressure |
OPTION FOR ALL AIR - COOLED UNITS
A = Packaged Air-cooled
H = Heat Reclaim Air-cooled
R = Remote Air-cooled |
a |
a |
2 = 2 - Way
3 = 3 - Way |
OPTION FOR ALL LIQUID-COOLED UNITS
W = Water-Cooled
G = Glycol-Cooled |
- |