Standard Features
TANDEM CHILLERS COMPACT LINE OF WATER COOLED CHILLERS HAS BEEN
DESIGNED WITH OVER 30 YEARS EXPERIENCE BEHIND IT.
We have taken over 30 years of chiller design, manufacturing and
field service experience and applied it to our COMPACT CHILLER line
to supply what we feel is the best compact chiller on the market
to-day.
THESE ARE SOME OF OUR STANDARD FEATURES:
1. All our COMPACT water cooled and glycol cooled condenser chillers
have been designed to be removed from the packaging in less than
one hour without interrupting your operating system, chilled water
flow, tower water flow and electrical power.
2. We have built-in casters that crank up and down so that the
unit can be moved in and out on its own without the need for forklift
trucks or pallet trucks.
3.
At the inlet of each evaporator and condenser we install a bronze
"Y" strainer for additional protection from contamination in the
chilled water or cooling tower water supply. We still recommend
the installation of our stainless steel inline 6" and 8" basket
strainer at the beginning of the piping run to our chillers in both
the cooling tower and chilled water main lines.
4. In the condenser water in and out lines we have installed ¾"
fittings with valves for cleaning of the condenser, if required.
5. Our exclusive "intelligent chiller control system" gives us
the most powerful control system available for our chillers. We
are able to give years of trouble-free operation without false trips,
and the chiller alarms problems before they happen. The control
system also has automatic compressor sequencing (lead / lag) for
even run time and timed starts to ease inrush current.
This is the best maintenance program you
can have!
The chiller senses six temperatures, four different pressures,
water flow, two digital inputs for compressor motor overload, phase
reversal, pump interlock and local/remote control of chiller. It
displays suction and discharge temperatures and pressures, water
in and out temperature, water flow, condenser inlet fluid temperature,
liquid refrigerant leaving the condenser, alarm settings and alarm
fault conditions, plus condenser sub-cooling, expansion valve super
heat and the actual cooling capacity of the chiller at any time.
6. Using our exclusive control system and a motorized condenser
water flow valve for head pressure control valve, we can operate
the chiller at the lowest possible condensing temperature, thereby
maximizing the compressor operating efficiency while maintaining
optimum thermal expansion valve performance. The chiller uses both
an oversized high-efficiency evaporator and condenser to maximize
the compressor efficiency. Both give us the highest energy savings
available of all compact chillers on the market to-day!
7. With a stainless steel frame, electrical control panel, evaporator,
condenser, and bolt-on panels you have a long lasting, non-rusting
chiller that will last for years.
8. We use ACR type L copper pipe and fittings in the manufacture
of our chillers. During brazing, nitrogen is used to prevent scale
from forming inside the pipes. All chillers are leak tested by pressurizing
the unit to 100 psi with nitrogen and holding the pressure overnight,
only then is a vacuum pulled and the unit charged with freon. The
chiller is run tested and a "test data sheet" completed to be used
as a comparison during start-up of the chiller.
9. We locate all controls, valves and filters where they are accessible
for inspection and maintenance without removal of the chiller, for
major service the chiller can easily removed.
10. We take extreme pride in every chiller we manufacture and back
up our chillers with our excellent warranty: 5 year compressor replacement
and 2 year parts warranty on the balance of the chiller.